4. Tape the heart rate cable connectors of the new cable to the cut end of the old cable. Verify
connection is secure.
5. Pull the old cable through bottom of handle until end of the new cable is up to the top of handle
opening.
6. Position the strain relief plug on heart rate cable 4” from connector.
WHITE OR RED
SHIELD OR BLACK
(4.0)
NOTE: ALL COILS MUST BE
CONTAIN WITHIN THIS
AREA
WITHIN THIS AREA
All coils must be contained
within this area.
7. Install the strain relief plug into hole on handle using a strain relief plier or needle nose pliers
and a rubber hammer. Do not to damage the heart rate wire. Verify strain relief plug is secure.
2
3
1
Description
1 Secure strain relief plug into handle
2 Heart rate cable
3 Plug in heart rate cable jack
8. Plug in the heart rate cable jack.
Install grips
1. Pull the black heart rate wire through the second lowest back hole.
2
3
1
5
4
Description
1 Front grip
2 White (or red) heart rate wire must be
on front side
3 Black heart rate wire must be on back
side
4 Screws (5)
5 Back grip