Cybex 525AT Arc Trainer Bedienungsanleitung Seite 64

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 74
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 63
64 65
Cybex Service Manual
Test the unit for proper operation
1. Plug the power cord into the power outlet.
2. Turn the main power switch to the on (I) position.
3. Operate the unit at all levels to verify proper operation.
MCC Board
Tools Required
Phillips screwdriver
ESD (Electrostatic Discharge) grounding strap
Disconnect power source
4. Turn the main power switch to the off (O) position.
5. Unplug the power cord from the power outlet.
WARNING: Shock and electrocution hazard
Unplug unit and let sit 10 minutes before cleaning or performing maintenance
Electrical charge can remain in unit after unplugging
Keep water and liquids away from electrical parts
NOTICE: Console damage
Wear an ESD grounding strap during this procedure. Connect ESD grounding strap to
frame bolts or unpainted metal of frame. If ESD grounding strap is not available, touch
frame bolts or unpainted metal of frame before handling any electronics.
Remove front cover
1. Remove the four short screws and one long screw securing the front cover and iPad clip to the
console assembly using a Phillips screwdriver.
2
1
3
4
Description
1 Console assembly
2 Short screws (4)
3 iPad clip
4 Long screw (1)
2. Tilt front cover forward.
Seitenansicht 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 73 74

Kommentare zu diesen Handbüchern

Keine Kommentare